Small high and low temperature test chamber: light and compact, small body and large volume, small footprint and light weight, 2 sets can be stacked. The equipment with a base area of 0.3㎡ weighs only 55kg, but its internal volume can reach 15.5L. There are twenty styles of products according to the content volume and temperature and humidity range. Meet -70~+150℃, 15.5L~64L temperature and humidity test requirements. Customized operation and program operation setting function The controller has a constant value operation setting that can be used for reliability testing, as well as a programming setting function for temperature and humidity combination alternation for temperature characteristic testing.
Model |
VT4002 |
VT4002 |
VT4004 |
VT6002 |
VT7004 |
VT7006 |
||
Power supply |
AC220V 50Hz |
|||||||
Maximum current (A) |
8 |
8 |
9 |
10 |
15 |
16 |
||
Maximum power consumption (Kw) |
1.8 |
1.8 |
2.0 |
2.2 |
2.5 |
3.0 |
||
Use ambient temperature and humidity |
-20℃ ~+30 ℃/< 85%RH |
|||||||
Sex Can Reference Number |
Temperature range |
-20 ℃,-40 ℃,-70 ℃ ~ +150 ℃ |
||||||
|
Temperature fluctuation |
≤±0.5℃ (no-load) |
||||||
|
temperature uniformity |
≤2.0℃ (no-load) |
||||||
|
heating time |
+25℃~+150℃ ≤1.0~5.0℃/min (no load) |
||||||
|
Cooling time |
+25℃~-70℃ ≤0.7~1.5℃/min (no load) |
||||||
Material Material |
Shell Material |
High quality cold rolled steel plate spray plastic |
||||||
|
liner material |
brushed stainless steel SUS-304S |
||||||
|
Thermal insulation material |
Polyurethane foam + superfine glass fiber cotton |
||||||
system Cold Department system |
Refrigeration mode |
mechanical single-stage auto-cascade |
||||||
|
Compressor Brand |
French fully enclosed Taikang compressor |
||||||
|
Compressor (HP) |
0.5 |
0.5 |
0.7 |
0.7 |
1.0 |
1.0 |
|
|
Evaporator |
Fin type multi-segment |
||||||
|
Condenser |
Fin-type wind condenser |
||||||
|
Solenoid valve |
Danfoss solenoid valve |
||||||
|
Refrigerant |
United States DuPont refrigerant R404a,F23 |
||||||
Heater |
Seamless stainless steel anti-dry heating tube |
|||||||
Circulating fan |
Centrifugal fan |
|||||||
Door viewing window |
Vacuum glass observation window |
|||||||
Temperature sensor |
Platinum resistance Pt100 |
|||||||
Temperature controller |
5.6 "true color touch screen/Chinese input/history curve record |
|||||||
Safety protection device |
Over-temperature alarm/compressor over-temperature protection/motor over-current protection/equipment leakage protection |
|||||||
Internal volume (L) |
15 |
20 |
36 |
20 |
36 |
64 |
||
Inner dimension (mm) |
D |
230 |
250 |
300 |
250 |
300 |
400 |
|
|
W |
310 |
320 |
400 |
320 |
400 |
400 |
|
|
H |
200 |
250 |
300 |
250 |
300 |
400 |
|
Outer dimension (mm) |
D |
530 |
560 |
730 |
630 |
730 |
780 |
|
|
W |
450 |
460 |
600 |
520 |
600 |
800 |
|
|
H |
620 |
670 |
980 |
870 |
980 |
1000 |
|
Weight approx. (Kg) |
50 |
60 |
75 |
70 |
90 |
100 |
||
Annex |
Wire hole (¢ 25.¢ 50.¢ 100 optional) special cork for testing |
|||||||
The performance is measured at an ambient temperature of +20°C without any load. |